① When the heating load is working within 30s, the NTC temperature is detected to exceed the target temperature by 5℃.
② When the heating function is executed, the preset time is exceeded.
Before replacing, make sure to turn off the printer and disconnect the power supply to ensure safe operation.
① Use the S2.5 Allen key to unscrew the housing fixing screws that fix the heating module.
② Use the S2.0 Allen key to unscrew the lower fixing screws of the housing and remove the housing.
③ Pull out the NTC wiring and reinstall it. Put the housing back.
④ Try to heat again to see if there is still an abnormality.
⑤ If there is still an abnormality, use the S2.0 Allen key to replace the NTC wiring.
Step 3: Install the housing
①Use the S2.0 and S2.5 Allen key to install the heating module housing.
②Try heating the resin again to see if the heating anomaly still exists.
If the above steps do not provide assistance or if you encounter any other issues during subsequent use, we recommend that you create a support ticket.
The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)
Please click this link to submit your ticket: