The X-axis Accelerometer gyroscope module is located on the internal left side of the adapter board in the print head.
S2.5 Allen Key
Flathead Screwdriver
Troubleshooting Steps:
Before troubleshooting, make sure to turn off the printer and disconnect the power to ensure safe operations.
Tilt the printer so that its bottom faces you.
①Use the S2.5 Allen Key to unscrew the 4 screws fixing the mainboard bottom cover.
②Disconnect the FAN2 fan cable from the mainboard and place the mainboard bottom cover aside.
①Use the Flathead Screwdriver to gently insert and pry open the fixed cable buckle accessories on both sides of the print head module.
②Replug both ends of the cable harness of the print head.
Note: If there is glue on the appearance, gently peel off the glue before unplugging the cable.
If the above steps do not provide assistance or if you encounter any other issues during subsequent use, we recommend that you create a support ticket. The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)
Please click this link to submit your ticket: