Before proceeding with the replacement, ensure that the printer is turned off and disconnect the power to ensure safe operations.
Unplug the left X-axis limit switch cable with the "X" label on the left side of the aluminum profile.
Use an M2.5 hex key to loosen the screw fixing the X-axis limit switch cover and remove the X-axis limit switch cover.
Use an M2.0 hex key to remove the screw fixing the limit switch.
Remove the limit switch and unplug the connection cable.
Replace the limit switch and reconnect the cable to the limit switch port.
Use an M2.0 hex key to secure the limit switch, ensuring the cable is placed in the casing groove.
Place the casing back onto the X-axis aluminum profile and use an M2.5 hex key to secure it.
Reconnect the limit switch connection cable.
If the above steps do not provide assistance or if you encounter any other issues during subsequent use, we recommend that you create a support ticket.
The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)
Please click this link to submit your ticket:
After-sales Ticket Submission Page