The X-axis Accelerometer gyroscope module of the Kobra 2 Pro is located on the internal left side of the adapter board in the print head.
S2.5 Allen Key
Flathead Screwdriver
Troubleshooting steps:
Before troubleshooting, make sure to turn off the printer and disconnect the power to ensure safe operation.
Tilt the printer, positioning its bottom towards the front.
Hold the latch on both sides of the touch screen cable to remove it, and then take the cable out of the slot.
① Use the S2.5 Allen Key to unscrew the 2 screws fixing the bottom plastic parts;
② Use a Phillips screwdriver to pry open the plastic parts along the indicated direction;
③ Take out the touch screen cable from the plastic parts;
④ Unplug the FAN2 fan cable on the mainboard and set aside the plastic parts.
①Use the flathead screwdriver to gently pry open the fixed wire clasp accessories on both sides of the print head module.
②Reconnect and disconnect the ends of the print head cable bundle.
Note: If there is glue on the appearance, gently remove the glue before pulling out the wires.