Before replacing the Y-axis belt, make sure to turn off the printer and disconnect the power supply to ensure safe operation.
①Turn the red knob of the Y-axis belt tensioner counterclockwise to remove it;
②Move the hot bed to the front, and use a wrench or other tool to move the copper buckle of the belt fixed on the hot bed to the left and remove it;
③Use the S2.0 Allen Key to unscrew the left and right screws that fix the tensioner;
④Take out the tensioner, and finally take the belt out of the tensioner pulley.
First, move the hot bed to the front position.
①Pass one end of the belt through the tensioner pulley;
②Use your hand to clamp the copper buckle of the belt to the fixed position of the sheet metal at the other end;
③Move to the right to the groove after being clamped.
① Install the Y-axis tensioner housing and tighten the 2 screws on the left and right;
② Turn the tensioner knob clockwise to the tightest and then turn it counterclockwise for one circle.
If the above steps do not provide assistance or if you encounter any other issues during subsequent use, we recommend that you create a support ticket.
The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)
Please click this link to submit your ticket:
After-sales Ticket Submission Page