● S2.5 Allen key
● S4.0 Allen key
Before replacing the switch power supply, make sure to turn off the printer and disconnect the power cord to ensure safe operation.
①Remove the handle that fixes the printing platform.
②Use the S4.0 Allen key to unscrew the cantilever fixing screws and remove the cantilever.
③Use the S2.5 Allen key to unscrew the strain gauge assembly protective shell.
④Remove the strain gauge connection line, use the S4.0 Allen key to unscrew the fixed strain gauge assembly screws and remove the assembly.
①Use the S4.0 Allen key to install the fixed strain gauge assembly.
②Connect the strain gauge connection line back to the adapter plate port.
③Install the protective shell and fix it with an S2.5 Allen key.
④ Install the cantilever assembly and use the S4.0 hexagonal wrench to install and fix it.
⑤ Reinstall the platform fixing handle.