S2.0 Allen key
S2.5 Allen key
S3.0 Allen key
Remove the cover, print platform, and resin vat. Before replacing the UV lamp board, make sure the device is turned off and the power is disconnected for safety.
Use the S2.0 Allen key to unscrew the 5 screws fixing the device's back cover. Take out the back cover and place it aside for later installation.
Refer to the diagram and disconnect the exposure screen cable, ground wire, motor cable, limit switch cable, and UV lamp cable from the motherboard.
The exposure screen cable has fixed high-temperature tape; you can remove the tape before unplugging.
|
|
① Lay the device down with the base facing you. Use the S3.0 Allen key to unscrew the 6 screws fixing the base.
② Since the top board is attached with stickers, tear open the edge of the stickers a bit for easy separation.
After tearing, separate the top board module from the base module.
|
|
|
With the base module facing you, use the S2.5 Allen key to unscrew the 6 screws fixing the UV lamp module. Remove the UV lamp module from the base module.
Note:
When removing the screws, support the UV lamp module slightly by hand to avoid the module from falling after the screws are removed, which may damage the components.
Use the S2.5 Allen key to unscrew the fixing screws on both sides of the UV module (2 screws on one side). Separate the lens module and UV lamp board.
Take out the new UV lamp board. Use the S2.5 Allen key to align it with the lens module and the screw holes from the previously removed UV lamp board. Tighten the screws.