Note: Raise the cantilever to the middle position before replacing the limit switch for easier replacement.
Before replacement, ensure the printer is turned off and the power is disconnected for safe operation.
Use the S3.0 hex key to loosen the two screws securing the fixed end cap.
① Use the S2.0 and S3.0 hex key to remove the fixed screws of the guide rail guard.
② Lift out the guide rail guard.
Use the S2.5 hex key to loosen the screws securing the limit switch.
<!--p.MsoNormal{ mso-style-name: 正文; mso-style-parent: ""; margin: 0pt; margin-bottom: .0001pt; mso-pagination: none; text-justify: inter-ideograph; mso-font-kerning: 1.0000pt; } p.paragraph{ mso-style-noshow: yes; margin-top: 5.0000pt; margin-right: 0.0000pt; margin-bottom: 5.0000pt; margin-left: 0.0000pt; mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; text-align: left; font-family: 等线; mso-bidi-font-family: 'Times New Roman'; font-size: 12.0000pt; } -->
① Take out the limit switch and unplug the connector of the connecting line.
② Replace the new limit switch and reconnect the connector to the limit switch port.
Use the S2.5 hex key to securely install the limit switch.
① Reinstall the guide rail guard.
② Use the S2.0 and S3.0 hex key to secure the guard screws.
Install the guide rail end cap and secure it using the S3.0 hex key.
If the above steps do not provide assistance or if you encounter any other issues during subsequent use, we recommend that you create a support ticket.
The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)
Please click this link to submit your ticket: