S3.0 Allen key
S2.0 Allen key
Before replacing the mainboard, make sure to turn off the device and disconnect the power for safe operation.
Remove the cover, washing bucket, curing platform, gooseneck lamp, etc., from the device to facilitate disassembly.
Lay the machine down with the bottom facing you. Use the S3.0 Allen key to remove the 4 self-tapping screws securing the bottom cover. Place the removed cover aside for later installation.
Remove the knob from the control panel.
①Use the S2.0 Allen key to loosen the 4 screws securing the control panel.
②Disconnect the cables from the control panel and remove the panel.
①Take out the new control panel and connect the cables.
②Align the screw holes on the control panel with those on the bottom shell. Use the S2.0 Allen key to initially tighten the 4 screws, then fully tighten each screw.
Take the previously removed knob and install it onto the control panel.
Connect the device to the power source and start it. Check if the touch functions and knob pressing provide normal feedback.
If there are any issues, please record a video and create an after-sales ticket to provide it to the after-sales engineer.
The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)
Please click this link to submit your ticket:
After-sales Ticket Submission Page
If there are no issues, turn off the device and disconnect the power source for safety.
Take the previously removed bottom cover, align it with the screw holes (aligning the bottom cover's heat dissipation holes with the mainboard position), and use the S3.0 Allen key to tighten the 4 self-tapping screws to secure the bottom cover.
If the above steps do not provide assistance or if you encounter any other issues during subsequent use, we recommend that you create a support ticket. The after-sales engineers will assist you in finding a solution to the problem(Reply time :1 working day)